A sensor faucet is four systems in one housing, and three of them fail identically from the outside. Diagnosis is elimination, cheapest check first.
The four systems
| System | Job | How it fails |
|---|---|---|
| Power | Battery pack or transformer | Flat battery, loose connector, lost supply |
| Sensor | Detects a hand at the window | Dirty or scratched lens, range wrong, reflection |
| Solenoid | Opens and closes the water | Stuck open, stuck closed, debris |
| Filter | Keeps grit from the solenoid | Clogged screen, reduced or no flow |
Dead, running, intermittent
Dead points at power first. In a house that is closed part of the year, a battery marginal in autumn is flat by reopening.
Running continuously needs the water isolated before anything else. Then work back: a solenoid held open, a failed seat, or a sensor reading a reflection.
Intermittent is usually range, reflection or a low battery, and the battery is the cheapest test.
New rooms, new sensors
Where a sensor fixture came in with a rebuild, an early failure is more likely to be debris from construction or a connection disturbed during finishing than a worn module.
That is checked before parts are ordered, because a module swap on a debris problem repeats itself.
Sediment
District supply arrives through tanks and pressure zones; a well brings grit. A clogged inlet screen stops flow while the solenoid clicks, so the screen is checked before the solenoid is condemned.
What the visit involves
The fixture is isolated — a stop, the property valve, or the pump. Power is checked, the window cleaned and inspected, the screen cleared, and the solenoid tested. The sensor's response is then checked with the water running.
Where a part is discontinued, the choice is a compatible module or a new fixture, answered before ordering.
Shared and guest spaces
A failed restroom tap in a shared building or a property with guests is a continuity problem as well as a plumbing one. The work is sequenced so the space stays usable, and the isolation is agreed with whoever runs it.
Repair or replace
Repair when the power supply, sensor, solenoid or filter is available and the body is sound. Replace when the module is discontinued, the body is damaged, or the fault cannot be isolated to a serviceable component.
Before the call
Say how the fixture behaves, how it is powered, whether the space is shared, whether the property is on a well, and whether a private lane is involved.
The line is answered 24 hours a day, and the address is checked against the published coverage on the call.