A sensor faucet is four systems in one housing, and from the basin three of them look identical when they fail. Diagnosis is elimination, cheapest check first.
The four systems
| System | Job | How it fails |
|---|---|---|
| Power | Battery pack or transformer | Flat battery, loose connector, lost supply |
| Sensor | Detects a hand at the window | Dirty or scratched lens, range wrong, reflection |
| Solenoid | Opens and closes the water | Stuck open, stuck closed, debris |
| Filter | Keeps grit from the solenoid | Clogged screen, reduced or no flow |
Power and the window cost nothing to check. The solenoid and filter are opened last.
Dead, running, intermittent
Dead points at power first. In a house that is closed part of the year, a battery that was marginal in autumn is flat by the time the house reopens.
Running continuously is the failure to act on. Isolate the water, then work back from the solenoid to the sensor. A reflective basin or an object left in range will hold a sensor open, and that is worth ruling out before parts are ordered.
Intermittent is usually range or reflection, and often a low battery. Replacing the battery pack is the cheapest test.
Sediment from a well
Some properties host on district supply, some on private wells. A well sends grit to the inlet screen faster, and a clogged screen stops flow while the solenoid clicks normally. If the screen keeps clogging, the answer is filtration or the well, not the faucet.
What the visit involves
The fixture is isolated — at a stop, or by the pump. The power source is checked, the window cleaned and inspected, the screen removed and cleared, and the solenoid tested for open and close. The sensor's response is then checked with the water running.
Where a part is discontinued, the choice is a compatible module or a new faucet, answered before anything is ordered.
Properties with guests
A failed restroom tap in a property that takes in guests is a continuity problem as well as a plumbing one. The work is sequenced so the space stays usable where it can, and the isolation is agreed with whoever runs the property.
Repair or replace
Repair when the power supply, sensor, solenoid or filter is available and the body is sound. Replace when the module is discontinued with no compatible part, the body is damaged, or the fault cannot be isolated to a serviceable component.
Before the call
Say whether the faucet never starts, runs on or works intermittently, whether it is battery or mains powered, whether the property is on a well, and whether a gate or private lane is involved. That narrows the four systems.
The line is answered 24 hours a day, and the address is checked against the published coverage on the call.