Touchless Faucet Not Working: Power, Sensor, Solenoid
A three-step order for diagnosing a sensor faucet, from batteries and lens to the solenoid and filter, and the symptoms that point at each.
A sensor faucet has three separate systems, and they fail in ways that look similar from the outside: no water at all. Diagnosing in the right order turns a mystery into a part, and the order is power, then sensing, then the valve.
Step one: power
Battery models are the most frequent cause of a dead sensor faucet. The battery box is usually under the sink, sometimes behind a panel, and a low battery often announces itself with a blink pattern before the unit stops entirely.
Mains-powered units have an adapter or a transformer, and the failure can be at the outlet, the connector or the control module. Before condemning the sensor, confirm power at the point the manufacturer specifies. This single step resolves a large share of "the faucet stopped working" calls, and it costs nothing to check.
Step two: the sensor window
The lens sits behind a small window that collects soap film, hard-water spots and cleaning residue. A dirty lens scatters or blocks the beam, and the faucet either ignores hands or triggers with nothing there.
Clean it with a soft cloth and a mild solution. Abrasive cleaners and paper towels can scratch the lens, and a scratched lens is a permanent fault. Reflections cause the opposite failure: a shiny basin, a stainless backsplash or an object left in the bowl bounces the beam back and holds the valve open. If the faucet runs only under certain conditions, look at what is in or around the basin before looking at the electronics.
Step three: the solenoid and the water path
When the unit clicks but no water flows, the signal is getting through and the valve is not opening. The solenoid does that work, and its diaphragm can be held shut by debris or fail with age. Many models have an inlet strainer ahead of the solenoid, and a clogged strainer produces weak or absent flow with a healthy solenoid.
The aerator is the other restriction. Good pressure at the supply with a weak stream at the spout is usually a clogged aerator or filter, not a failing valve. Check the stop under the sink as well: a partly closed or seized stop looks exactly like a solenoid fault from above.
Calibration and range
Some sensor faucets have a detection range or mode that is set with a button, a remote or a sequence at the sensor. If the unit triggers from too far away, or only when a hand is almost touching it, the setting may have changed rather than the hardware failed. The manufacturer's sequence is the only reliable way to adjust it; guessing can leave the unit in a mode that will not run.
When to repair and when to replace
Commercial sensor faucets are built to be serviced. Power module, sensor, solenoid, filter and aerator are separate parts on most models, which means most faults are a part rather than a fixture.
Replacement becomes the answer when the control module is obsolete and unavailable, when the body is damaged, or when the unit is a sealed domestic model with no serviceable parts. In a commercial restroom, the availability of parts is worth knowing before a failure, because a discontinued module can take a fixture out of service for good.
What to have ready
Say whether the unit is battery or mains powered, whether it clicks, and whether the flow is weak or absent when it does trigger. Add the fixture's make and model if it is visible. Those answers usually identify the part before anyone arrives, which is the difference between a repair and an exploratory visit.